Low-voltage main distribution

ML-SVC400

400 V Modular Low-Voltage Switchboard

Licensed fixed-pattern SIVACON platform for modular low-voltage main distribution.

Licensed platform: SIVACON 8PT4000Test and conformity evidence available
View technical data

Reference product views - final lineup follows approved project documents.

System voltage / frequency400 V / 50 Hz
Main busbar current1600-4000 A
Short-time withstand current80 kA
Feeder busbar current1000-2400 A

For controlled power distribution

Licensed modular LV switchboard

ML-SVC400 is Minglang's licensed-platform low-voltage assembly based on SIVACON 8PT4000. The page states the documented Minglang reference while project configuration and the applicable licensed scope are confirmed during technical review.

  • 01Licensed SIVACON platform
  • 02Modular fixed-pattern arrangement
  • 03Multiple published enclosure protection options

Customer benefits

Clear evidence, controlled configuration and practical delivery

Benefits are expressed around the engineering and project workflow, with product claims kept tied to the documented reference.

01

Defined selection basis

Published reference ratings give engineering and procurement teams a clear starting point for technical comparison.

02

Project-engineered configuration

Busbar, protection, interfaces and panel arrangement are confirmed against the approved single-line diagram and project documents.

03

Controlled evidence mapping

Available test and conformity evidence available is reviewed against the offered model, rating and construction before submission.

04

Documented handover

Approved drawings, inspection records and final documents are organized around the released project configuration.

Technical data

Certified reference configuration

Published values are catalogue references. The offered configuration is confirmed against the approved single-line diagram, data sheets and project interfaces.

Typical applications
Industrial main distributionInfrastructureCommercial facilitiesPower-system auxiliaries
System voltage / frequency400 V / 50 Hz
Main busbar current1600-4000 A
Short-time withstand current80 kA
Feeder busbar current1000-2400 A
Feeder busbar withstand65 kA
Rated insulation voltageUi 1000 V incoming/feeder - 800 V control
Degree of protectionIP42 / IP41 / IP40 / IP31 / IP30
PlatformSIVACON 8PT4000 licensed platform

Outline and dimensions

Reference envelope for early layout work

Typical reference panel: 600 W x 800 D x 2200 H mm

Final dimensions are subject to the approved general arrangement.
Front view
Side view

Find out more

Technical resources

Use published documents for preliminary review. Applicability to a project offer is confirmed during technical clarification.

Product questions

What to confirm before selection

What is the published reference for ML-SVC400?

The page lists the catalogue reference configuration for ML-SVC400. Final ratings and interfaces remain subject to the approved project documents.

Are the published dimensions fixed for every project?

No. The dimensions are a documented reference envelope. Final width, depth, height and lineup arrangement depend on the selected devices, ratings, cable interfaces and approved general arrangement.

What evidence can be requested?

Test and conformity evidence available can be reviewed for applicability to the offered model and configuration. Project-specific routine verification is handled separately during manufacturing and release.

Project-specific review

Define the ratings, interfaces and evidence required for your project.